How to Read a Certificate of Analysis Before Accepting a Chemical Delivery
A Certificate of Analysis (CoA) is one of the most important documents in chemical procurement, and one of the most often ignored. Many mines and industrial plants accept chemical deliveries after a quick glance at the paperwork, only to discover later that the product was off-specification. This guide explains what a CoA is, how to read each section and the warning signs that should make you stop before offloading.
What Is a Certificate of Analysis?
A Certificate of Analysis is a document issued by the manufacturer or an accredited laboratory that confirms the test results for a specific batch of product. It shows that the chemical delivered meets, or does not meet, the agreed specification.
A CoA is different from a Safety Data Sheet (SDS). The SDS explains hazards and safe handling for the product in general. The CoA proves the quality of the specific batch you received.
Why the CoA Matters
- Protects your process: Off-spec acid, reagents or manganese products can reduce recovery, damage equipment or contaminate products.
- Protects your money: You pay for the concentration and purity you ordered.
- Supports claims: If a product fails, the CoA and your own test results support a rejection or credit claim.
- Supports compliance: Auditors and regulators may ask for quality records.
The Key Sections of a CoA
1. Supplier and laboratory details
The name and address of the manufacturer, and the laboratory that performed the tests. Check whether the laboratory is the producer's own quality-control lab or an independent accredited lab.
2. Product name and grade
The exact product, such as "Sulphuric Acid 98% Technical Grade" or "Electrolytic Manganese Dioxide – Alkaline Grade". It must match your purchase order.
3. Batch or lot number
This is critical. The batch number on the CoA must match the batch number on the drums, bags, tanker documents or delivery note. A CoA for a different batch proves nothing about what you received.
4. Manufacturing and test dates
Check that the test date is recent and makes sense with the delivery date. Very old CoAs, or a test date after the delivery, are warning signs. Also check expiry or retest dates for products with limited shelf life.
5. Test parameters, specifications and results
This table is the heart of the CoA. It usually shows:
| Column | What it means |
|---|---|
| Parameter | What was tested, such as concentration, iron content or moisture |
| Specification / limit | The acceptable range, such as "98.0% min" or "Fe 50 ppm max" |
| Result | The actual measured value for this batch |
| Method | The test method used, often a standard such as ASTM or ISO |
| Unit | %, ppm (parts per million), mg/kg, etc. |
Compare every result against your purchase specification, not only the supplier's. A result may pass the supplier's standard but fail your contract limit.
6. Conclusion and authorisation
A statement that the product complies (or does not comply) with specification, signed or authorised by a responsible quality officer, with the company stamp where applicable.
Example: Reading a Sulphuric Acid CoA
- H2SO4 concentration: Should meet the minimum, for example 98% min.
- Iron (Fe): Check against your maximum limit, as excess iron can affect SX-EW.
- Chloride and other impurities: Check limits relevant to your plant and equipment.
- Appearance and colour: Should be consistent with the grade.
- Batch number: Must match the tanker documentation.
Warning Signs of a Problem CoA
- No batch number, or a batch number that doesn't match the delivery
- Results exactly the same as the last several deliveries (possibly copied)
- Missing test methods or units
- No signature, name or laboratory details
- Obvious editing, mismatched fonts or poor-quality copies
- Results suspiciously exactly on the specification limit for every parameter
- Test dates that don't make sense
A Simple Acceptance Procedure
- Receive the CoA before or with the delivery.
- Check that the product, grade and batch number match the purchase order and delivery note.
- Compare every result with your contract specification.
- Check quantity against weighbridge tickets.
- Take a representative sample for your own laboratory, especially for new suppliers or critical chemicals.
- Retain samples and records for each batch.
- If anything fails, quarantine the product and notify the supplier in writing before use.
Frequently Asked Questions
Is a Certificate of Analysis the same as a Safety Data Sheet?
No. The CoA confirms the quality test results for a specific batch, while the SDS describes hazards, handling and emergency measures for the product.
Should I still test a product if it has a CoA?
For critical chemicals and new suppliers, yes. Independent sampling confirms the CoA and protects your process.
What should I do if the CoA shows off-spec results?
Do not offload or use the product. Quarantine it, inform the supplier in writing and agree on replacement or credit.
π§° Recommended Tools for Checking Deliveries
Kit to sample and verify chemicals against the supplier's CoA.
- Digital Lab Scale (0.01 g) – accurate sample weighing
- Write-On Sample Bags – label and retain every delivery sample
- HDPE Sample Bottles – safe for liquid chemical samples
- Waterproof Labels & Markers – clear batch and date labelling
Want chemicals that come with a full Certificate of Analysis? Request a G & Y quote
Quality-Assured Chemical Supply
G & Y Solutions Limited supplies sulphuric acid, mining reagents and manganese products with a Certificate of Analysis for every load, along with Safety Data Sheets and full delivery documentation. See our guides on smelter acid vs sulphur-burnt acid and safe acid storage.
π Call +260 975 574 784 | π¬ WhatsApp +260 966 807 585 | ✉️ sales@gandysolutions.com